Anastomotic leakage (AL) is a serious complication occurring after esophagectomy. The current knowledge suggests that inadequate intraoperative perfusion in the anastomotic site contributes to an increase in the AL rate. Presently, clinical estimation undertaken by surgeons is not accurate and new technology is necessary to improve the intraoperative assessment of tissue oxygenation. In the present study, we demonstrate the application of a novel optical technology, namely Single Snapshot imaging of Optical Properties (SSOP), used to quantify StO2% in an open  surgery experimental gastric conduit (GC) model. After the creation of a gastric conduit, local StO2% was measured with a preclinical SSOP system for 60 min in the antrum (ROI-A), corpus (ROI-C), and fundus (ROI-F). The removed region (ROI-R) acted as ischemic control. ROI-R had statistically significant lower StO2% when compared to all other ROIs at T15, T30, T45, and T60 (p < 0.0001). Local capillary lactates (LCLs) and StO2% correlation was statistically significant (R = -0.8439, 95% CI -0.9367 to -0.6407, p < 0.0001). Finally, SSOP could discriminate resected from perfused regions and ROI-A from ROI-F (the future anastomotic site). In conclusion, SSOP could well be a suitable technology to assess intraoperative perfusion of GC, providing consistent StO2% quantification and ROIs discrimination.

Single snapshot imaging of optical properties (SSOP) for perfusion assessment during gastric conduit creation for esophagectomy: An experimental study on pigs

Cinelli L.;Elmore U.;Rosati R.;Partelli S.;
2021-01-01

Abstract

Anastomotic leakage (AL) is a serious complication occurring after esophagectomy. The current knowledge suggests that inadequate intraoperative perfusion in the anastomotic site contributes to an increase in the AL rate. Presently, clinical estimation undertaken by surgeons is not accurate and new technology is necessary to improve the intraoperative assessment of tissue oxygenation. In the present study, we demonstrate the application of a novel optical technology, namely Single Snapshot imaging of Optical Properties (SSOP), used to quantify StO2% in an open  surgery experimental gastric conduit (GC) model. After the creation of a gastric conduit, local StO2% was measured with a preclinical SSOP system for 60 min in the antrum (ROI-A), corpus (ROI-C), and fundus (ROI-F). The removed region (ROI-R) acted as ischemic control. ROI-R had statistically significant lower StO2% when compared to all other ROIs at T15, T30, T45, and T60 (p < 0.0001). Local capillary lactates (LCLs) and StO2% correlation was statistically significant (R = -0.8439, 95% CI -0.9367 to -0.6407, p < 0.0001). Finally, SSOP could discriminate resected from perfused regions and ROI-A from ROI-F (the future anastomotic site). In conclusion, SSOP could well be a suitable technology to assess intraoperative perfusion of GC, providing consistent StO2% quantification and ROIs discrimination.
2021
Anastomotic leak
Esophageal resection
Esophagectomy
Gastric conduit
Ivor Lewis
Optical properties
Perfusion assessment
Single snapshot
Spatial frequency domain imaging
SSOP
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11768/121616
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact